13.4. Battery Thermal System Cooling Fan Control - BatThermSysCoolgFanCtl
Id |
BatThermSysCoolgFanCtl |
Title |
Battery Thermal System Cooling Fan Control |
System |
Thermal |
Document Type |
Application Software Component Specification Preview |
13.4.1. Ports
Id |
Direction |
Data Type |
Dimensions |
Unit |
|
|---|---|---|---|---|---|
1 |
BatCooltTAct |
Incoming |
single |
[-1] |
inherit |
2 |
BTSSystemState |
Incoming |
Enum: VtSig_BTSSystemState_t |
[-1] |
inherit |
3 |
AmbT |
Incoming |
single |
[-1] |
inherit |
4 |
BatCooltVlvRadrReq |
Incoming |
boolean |
[-1] |
inherit |
5 |
CmprDchaP |
Incoming |
single |
[-1] |
inherit |
6 |
BatFanSpdReq |
Outgoing |
uint8 |
[-1] |
inherit |
7 |
BatFanSpdReq_send |
Outgoing |
boolean |
[1] |
inherit |
13.4.2. Parameters
Id |
Data Type |
Dimensions |
Range |
Unit |
Description |
|
|---|---|---|---|---|---|---|
1 |
BtscfcCmprOverPFanReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
target cooling fan duty cycle in %, when the AC system has an overpressure condition |
2 |
BtscfcCmprOverPThd |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
maximum permitted pressure in the AC system in bar to trigger maximum fan speed |
3 |
BtscfcFanSpdTblDeltaTAxis |
single |
[1,6] |
Min: 0, Max: 100 |
degC |
the coolant temperature delta to ambient in degC when the system is in state COOLING and the radiator coolant valve is OPEN |
4 |
BtscfcFanSpdTblReqAxis |
single |
[1,6] |
Min: 0, Max: 100 |
% |
target cooling fan duty cycle in % |
5 |
BtscfcSwtLvl1To2DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
6 |
BtscfcSwtLvl2To1DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
7 |
BtscfcSwtLvl2To3DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
8 |
BtscfcSwtLvl3To2DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
9 |
BtscfcSwtLvl3To4DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
10 |
BtscfcSwtLvl4To3DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
11 |
BtscfcSwtLvl4To5DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
12 |
BtscfcSwtLvl5To4DchaP |
single |
[1,1] |
Min: 0, Max: 35 |
bar |
switching pressure in bar, for the cooling fan duty cycle request |
13 |
BtscfcLvl1FanSpdReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
configurable fan duty cycle in % |
14 |
BtscfcLvl2FanSpdReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
configurable fan duty cycle in % |
15 |
BtscfcLvl3FanSpdReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
configurable fan duty cycle in % |
16 |
BtscfcLvl4FanSpdReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
configurable fan duty cycle in % |
17 |
BtscfcLvl5FanSpdReq |
uint8 |
[1,1] |
Min: 0, Max: 100 |
% |
configurable fan duty cycle in % |