4.18. Input Discrete Signal Monitor - InpDisSigMonr

Id

InpDisSigMonr

Title

Input Discrete Signal Monitor

System

Drivetrain

Document Type

Application Software Component Specification Preview

4.18.1. Ports

Id

Direction

Data Type

Dimensions

Unit

1

BrkgSysVld1

Incoming

boolean

[1]

inherit

2

BrkPedlSt

Incoming

Enum: com_vOnOff_t

[1]

inherit

3

BrkPedlVld

Incoming

boolean

[1]

inherit

4

GearPosnAct

Incoming

Enum: CmnenaGearSt

[1]

inherit

5

GearPosnVld

Incoming

boolean

[1]

inherit

6

VsmStAct

Incoming

Enum: VSM_State_Enum

[1]

inherit

7

VsmStVld

Incoming

boolean

[1]

inherit

8

SafeRstEnad

Incoming

boolean

[1]

inherit

9

IndsmonBrkgSysVld

Outgoing

boolean

[1]

inherit

10

IndsmonGearSelrVld

Outgoing

boolean

[1]

inherit

11

IndsmonVsmSysVld

Outgoing

boolean

[1]

inherit

12

IndsmonBrkPedlStVldd

Outgoing

Enum: com_vOnOff_t

[1]

inherit

13

IndsmonGearPosnActVldd

Outgoing

Enum: CmnenaGearSt

[1]

inherit

14

IndsmonVsmStVldd

Outgoing

Enum: VSM_State_Enum

[1]

inherit

15

IndsmonSwtFltDiag

Outgoing

boolean

[6]

inherit

4.18.2. Parameters

Id

Data Type

Dimensions

Range

Unit

Description

1

IndsmonBrkStFlgSwtCt

uint8

[1,1]

Min: 3, Max: 200

Maximum number of switching of Brake pedal signal during the check period

2

IndsmonBrkStFlgSwtTi

single

[1,1]

Min: 0.03, Max: 100

sec

Time period for Brake pedal state signal switching check

3

IndsmonGearActSwtCt

uint8

[1,1]

Min: 3, Max: 200

Maximum number of switching of Gear Selector state signal during the check period

4

IndsmonGearActSwtTi

single

[1,1]

Min: 0.03, Max: 100

sec

Time period for Gear Selector state signal switching check

5

IndsmonVsmStSwtCt

uint8

[1,1]

Min: 3, Max: 200

Maximum number of switching of Vehicle State Manager state signal during the check period

6

IndsmonVsmStSwtTi

single

[1,1]

Min: 0.03, Max: 100

sec

Time period for Vehicle State Manager state signal switching check